WATERBORNE INORGANIC POST-TREATMENT

Waterborne inorganic post-treatment for hot-dip galvanized steel

HG-100 is a clear, waterborne inorganic post-treatment coating for hot-dip galvanized products. Inorganic particles bond with the zinc layer to inhibit initial oxidation and delay white rust and black staining. It supports in-line treatment on galvanizing and tube-production lines, as well as corrosion-resistance enhancement of finished products before dispatch, preserving surface quality during storage and distribution.

0.5㎛ ↓
Thin treatment layer designed to minimize changes to appearance and dimensions
Water-based
Clear, colorless and odorless water-based formulation; no organic constituents or oil
12 months
Shelf life from the date of manufacture; protect from freezing

Based on the property data in the product catalog and technical data sheet (TDS).

HG-100 — For Hot-dip Galvanized Products

In-line post-treatment and corrosion-resistance enhancement of finished products

HG-100 inhibits initial zinc oxidation and delays white rust and black staining. In-line treatment after galvanizing or application to finished products before dispatch maintains surface quality during storage and distribution.

Waterborne inorganic formulation

A water-based formulation described in the product data as odorless and free of organic constituents and specified hazardous solvents.

Inhibition of zinc-layer oxidation

Inorganic constituents interact with the zinc layer to inhibit oxidation.

Delayed white rust and black staining

Delays white and black corrosion products to help reduce appearance-related complaints.

Adhesion in Subsequent Processes

The oil-free inorganic formulation supports subsequent processes such as cement bonding or painting.

PropertyHG-100Notes
Appearance / OdorClear and colorless / odorlessWater-based formulation
Solids Content20±1% 
Treatment Thickness0.5 µm or lessThin layer; minimal change in appearance
Viscosity / pHWater-like / pH 11–12 
VOCsNear 0As listed in the catalog property table
Dilution / ApplicationConcentrate 1 : water 2–4 (by mass)Air spray / electrically powered HVLP gun
Storage12 months from manufactureProtect from Freezing
01

In-line Application on a Galvanizing Line

Cool the surface → remove water → confirm a substrate temperature of 35–40°C → apply → allow to dry naturally. Post-treatment after galvanizing helps control white rust during pipe storage and distribution.

02

Finished-product Application

Confirm a substrate temperature of 10–40°C → apply → blow off any pooled liquid. Used to add protection to already-galvanized finished products.

The catalog includes comparative corrosion-test photographs for hot-dip galvanized specimens against chromate treatment (SST up to 120 hr), round tubes against varnish (SST up to 240 hr), and steel wire at 1:2 dilution (neutral salt spray, 192 hr). Detailed documents are available on request.

APPLICATIONS

Applications in tube production, galvanizing and finished-product treatment

Hot-dip Galvanized Tubes and Pipes

In-line post-treatment for round and square tubes to help control white rust during storage and distribution. (HG-100)

Finished Hot-dip Galvanized Products

Additional protection and appearance retention for finished products before shipment. (HG-100)

Substrates for Subsequent Painting or Cement Bonding

Evaluate the oil-free inorganic formulation where subsequent paint or cement adhesion is required.

Storage and Distribution Quality

Supports appearance quality management during extended storage, ocean freight and other demanding distribution conditions.

Transition to waterborne post-treatment

Sample evaluation is available for lines considering a water-based alternative to corrosion-preventive oils or chromate post-treatment.

The product catalog reports no detection for the specified VOC and RoHS-related substance test items. Refer to the individual test reports for scope and detection limits.

PRODUCT ANSWERS

HG-100: Key Questions

Review the application requirements for this hot-dip galvanizing post-treatment.

What is HG-100?

A clear water-based inorganic treatment designed to delay white and black corrosion products and enhance the protection of hot-dip galvanized steel.

Where can it be incorporated into a process?

It can be used for in-line post-treatment on galvanizing or tube-making lines, or for additional protection of finished products before shipment.

What should be reviewed before product selection?

Review the galvanizing process, part geometry, subsequent painting, drying equipment, required corrosion-test duration and appearance criteria.

Discuss your HG-100 application